Product Details
Place of Origin: China
Brand Name: TC
Certification: UL, RoSH, REACH, CE
Model Number: FTP-31-6-4P
Payment & Shipping Terms
Minimum Order Quantity: 50 Boxes
Price: Negotiable
Packaging Details: Seaworthy Packing
Payment Terms: Western Union, T/T, L/C, MoneyGram
Type: |
Cat 6 F/UTP |
Outer Jacket: |
PE, Black |
Cross Spline: |
PE |
Insulation: |
HDPE |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Rip Cord: |
No |
Drain Wire: |
Yes |
Type: |
Cat 6 F/UTP |
Outer Jacket: |
PE, Black |
Cross Spline: |
PE |
Insulation: |
HDPE |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Rip Cord: |
No |
Drain Wire: |
Yes |
FTP Cat6 Cable Outdoor 23AWG Bare Copper PE Jacket
TC's FTP-31 series, outdoor Cat 6 shielded cabling system has test frequency up to 350MHZ, higher than other Cat 6 cables with industry standard of 250MHz.
Product Features
TC's Cat 6, 23 AWG, 4-pair, shielded outdoor cable adopts the excellent cross spline and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation and NEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards and ensure high-speed and stable cable transmission.
At the same time, it acts on the requirements for renovation projects and structured cabling in new buildings.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2
Technical Details
Transmission Performance | Cat.6 | TC | |||||
Frequency (MHz) | 4 | 31.25 | 62.5 | 100 | 200 | 250 | 350 |
IL Attenuation (dB/100M) | 3.4 | 9.5 | 13.5 | 17.2 | 24.8 | 28 | 31 |
Near End Crosstalk Attenuation (NEXT, dB) | 94 | 85.4 | 69.5 | 81.9 | 70.8 | 67.9 | 62.4 |
NEXT Power and PS NEXT (dB) | 73.9 | 69.9 | 61.7 | 64.3 | 59.6 | 61 | 58.6 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 108.9 | 99.2 | 90.7 | 107.2 | 82.8 | 77.2 | 74.6 |
ACR-F Power and PS ACR-F (dB) | 94.4 | 91.2 | 87.9 | 90.5 | 77 | 73.8 | 70.5 |
Return Loss (RL, dB) | 37.3 | 37.5 | 37.3 | 31.6 | 23.4 | 24.2 | 22.8 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Electrical Properties | |
DC resistance (20℃ ) |
93.8Ω/km
|
Earth Capacity | ≦ 5.6 nF/100m (@1kHz) |
100MHz Characteristic Impedance |
100Ω±15Ω
|
Transverse Conversion Loss (TCL) |
≥ 55dB-20×lgf (100-250MHz)
|
Delay Skew |
45ns/100m
|
NVP |
69%
|
Power Over Ethernet (POE)
|
Enhanced Power Over Ethernet under IEEE 802.3at
|
Mechanical Properties | |
Anti-Extrusion Capacity | 1000N/10cm |
Anti-Shock Capacity | ≥ 10 times |
Installation Temperature Range | -0℃ ~+40℃ |
Working Temperature Range |
-40℃ ~+60℃
|