PVC Sheath Zigzag UTP Cat 6A Cable 23AWG Cat 6A Network Cable

Product Details

Place of Origin: China

Brand Name: TC

Certification: UL, RoSH, REACH, CE

Model Number: UTP-11-6A-4PD-V1

Payment & Shipping Terms

Minimum Order Quantity: 50 Boxes

Price: Negotiable

Packaging Details: Seaworthy Packing

Payment Terms: Western Union, T/T, L/C, MoneyGram

Get Best Price
Highlight:

23AWG Cat 6a Cable

,

Zigzag Cat 6A Cable

,

23AWG cat 6 network cable

Type:
Cat 6A UTP
Conductor Material:
99.99% BC
Conductor OD:
23 AWG
Drain Wire:
No
Cross Spline:
PE
Insulation:
HDPE
Rip Cord:
Yes
Outer Jacket:
Serrated
Type:
Cat 6A UTP
Conductor Material:
99.99% BC
Conductor OD:
23 AWG
Drain Wire:
No
Cross Spline:
PE
Insulation:
HDPE
Rip Cord:
Yes
Outer Jacket:
Serrated
PVC Sheath Zigzag UTP Cat 6A Cable 23AWG Cat 6A Network Cable

Cat 6A Cable, Cat 6A Network Cable, UTP Cat 6A Cable with Zigzag PVC Sheath Application


It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels. As a crucial part of structured structured cabling, horizontal cabling calls for higher reliability and compatibility.

 

TC's UTP-11 series, indoor Cat 6A unshielded cabling system, has test frequency up to 600MHZ, higher than other Cat 6A cables with industry standard of 500MHz.

 

In the meantime, it supports 10G Base-T applications and Power Over Ethernet (POE/POE+).
 

 

Product Features


TC's Cat 6A, 23 AWG, 4-pair, unshielded indoor cable adopts cross-type spline and serrated outer jacket, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.

 

At the same time, it acts on the requirements for high transmission in data center, and structured structured cabling in new buildings.
 

 

Application Standards


GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2

 

 

Technical Details

 

  Transmission Performance Cat.6A TC
Frequency (MHz) 4 31.25 62.5 100 300 500 600
IL Attenuation (dB/100M) 3.4 9.7 13.9 17.7 32.2 43 46
Near End Crosstalk Attenuation (NEXT, dB) 89.4 77.9 78 72.5 63.4 58.6 54.3
NEXT Power and PS NEXT (dB) 77.6 72 63.2 61.3 51.3 49.9 46.8
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) 88.4 85 81.5 79.9 66.3 52 48.9
ACR-F Power and PS ACR-F (dB) 77.6 71.5 64.9 61.3 51.3 48.4 43
Return Loss (RL, dB) 37.1 35.3 34.4 28.5 24.6 21.1 19.8


Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

 
 
  Physical Specifications
Conductor Size (nominal value)
4×2×0.55 (AWG23)
Outer Diameter of Cable (nominal
value)
8.4mm
Weight (305m, with package,
nominal value)
17kg

 

 

  Electrical Properties
DC resistance (20℃ )
93.8Ω/km
Earth Capacity ≦ 5.6 nF/100m (@1kHz)
100MHz Characteristic Impedance
100Ω±15Ω
Transverse Conversion Loss (TCL)
≥ 55dB-20×lgf (100-2000MHz)
Delay Skew 25ns/100m
NVP
69%
Power Over Ethernet (POE) Enhanced Power Over Ethernet under IEEE 802.3at

 

 

  Mechanical Properties
Minimum Bend Radius (dynamic)
33mm
Minimum Bend Radius (static)
66mm
Maximum Installation Tension
100N
Anti-Extrusion Capacity 1000N/10cm
Anti-Shock Capacity ≥ 10 times
Installation Temperature Range -0℃ ~+40℃
Working Temperature Range -20℃ ~+75℃

 

 

  Flammability (PVC)
PVC Flame Resistance GB/T 18380.12 (IEC 60332-1-2)
Fire Rating CM UL 1581/ UL 1666

 

 

  Flammability (LSZH)
Flame Resistance (of single wire) GB/T 18380.12 (IEC 60332-1-2)
Smoke Density GB/T 17651 (IEC 61034-1/-2)
Hazardous Halogen Gas GB/T 17650.1/.2 (IEC 60754-1/-2)