Send Message
products
products
Home > products > Bulk Network Cable > FTP Cat6 Cable Outdoor 23AWG Bare Copper PE Jacket

FTP Cat6 Cable Outdoor 23AWG Bare Copper PE Jacket

Product Details

Place of Origin: China

Brand Name: TC

Certification: UL, RoSH, REACH, CE

Model Number: FTP-31-6-4P

Payment & Shipping Terms

Minimum Order Quantity: 50 Boxes

Price: Negotiable

Packaging Details: Seaworthy Packing

Payment Terms: Western Union, T/T, L/C, MoneyGram

Get Best Price
Highlight:

PE HDPE cat6 utp cable

,

FTP Outdoor cat6 utp cable

,

FTP Outdoor cat6 patch cable

Type:
Cat 6 F/UTP
Outer Jacket:
PE, Black
Cross Spline:
PE
Insulation:
HDPE
Conductor Material:
99.99% BC
Conductor OD:
23 AWG
Rip Cord:
No
Drain Wire:
Yes
Type:
Cat 6 F/UTP
Outer Jacket:
PE, Black
Cross Spline:
PE
Insulation:
HDPE
Conductor Material:
99.99% BC
Conductor OD:
23 AWG
Rip Cord:
No
Drain Wire:
Yes
FTP Cat6 Cable Outdoor 23AWG Bare Copper PE Jacket

FTP Cat6 Cable Outdoor 23AWG Bare Copper PE Jacket

 

It can be applied in outdoor horizontal cabling, the portion of a telecommunications cabling system.

 

In the meantime, it supports the latest 5G Base-T applications and Power Over Ethernet (POE/POE+).

 

 

Product Features
 

TC's Cat 6, 23 AWG, 4-pair, shielded outdoor cable adopts the excellent cross spline and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation and NEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards and ensure high-speed and stable cable transmission.

 

At the same time, it acts on the requirements for renovation projects and structured cabling in new buildings.

 

 

 

Technical Details

 

  Transmission Performance Cat.6 TC
Frequency (MHz) 4 31.25 62.5 100 200 250 350
IL Attenuation (dB/100M) 3.4 9.5 13.5 17.2 24.8 28 31
Near End Crosstalk Attenuation (NEXT, dB) 94 85.4 69.5 81.9 70.8 67.9 62.4
NEXT Power and PS NEXT (dB) 73.9 69.9 61.7 64.3 59.6 61 58.6
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) 108.9 99.2 90.7 107.2 82.8 77.2 74.6
ACR-F Power and PS ACR-F (dB) 94.4 91.2 87.9 90.5 77 73.8 70.5
Return Loss (RL, dB) 37.3 37.5 37.3 31.6 23.4 24.2 22.8


Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

 
 
  Physical Specifications
Conductor Size (nominal value)
4×2×0.57 (AWG23)
Outer Diameter of Cable (nominal
value)
7.5mm
Weight (305m, with package,
nominal value)
18kg

 

 

 

  Mechanical Properties
Minimum Bend Radius (dynamic)
30mm
Minimum Bend Radius (static)
60mm
Maximum Installation Tension
100N
Working Temperature Range
-40℃ ~+60℃